Customization: | Available |
---|---|
Pattern: | Column Cylinder Type |
Transform Type: | Resistance Strain |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Capacity(t) | 0.5~3 | 4~7 | 10~30 | 40~100 | 150~200 | 300 | 500 |
D | Φ59 | Φ59 | Φ88 | Φ126 | Φ150 | Φ185 | Φ233 |
D1 | Φ38 | Φ38 | Φ56 | Φ90 | Φ115 | Φ125 | Φ135 |
H | 88 | 96 | 130 | 178 | 270 | 330 | 385 |
SR | 15 | 15 | 20 | 60 | 70 | 80 | 120 |
M | M6 | M6 | M8 | M10 | M16 | M20 | M24 |
h | 8 | 8 | 10 | 15 | 20 | 25 | 30 |
Specification | ||||||
Model | HMD2017/TY2017 | |||||
Unit | 0.5t~50t | 70t~500t | ||||
Accuracy class | %F.S | 0.03 | 0.05 | 0.1 | 0.2 | 0.3 |
Output sensitivity | mV/V | 2.0±0.25% | 1.5±0.25% | |||
Nonlinearity | %F.S | ±0.03 | ±0.05 | ±0.1 | ±0.2 | ±0.3 |
Repeatability | %F.S | 0.02 | 0.03 | 0.05 | 0.1 | 0.15 |
Hysteresis | %F.S | 0.03 | 0.05 | 0.1 | 0.2 | 0.3 |
Creep (30 min) | %F.S | ±0.03 | ±0.05 | ±0.1 | ±0.2 | - |
Temperature effect on zero | %F.S/10ºC | ≤0.003 | ≤0.005 | ≤0.01 | ≤0.02 | ≤0.03 |
Temperature effect on output | %F.S/10ºC | ≤0.003 | ≤0.005 | ≤0.01 | ≤0.02 | ≤0.03 |
Zero output | %F.S | ±1 | ±2 | ±2 | ±5 | ±5 |
Input resistance | Ω | 400±30 | ||||
Output resistance | Ω | 350±3 | ||||
Insulation resistance | MΩ | ≥5000 | ≥2000 | ≥1000 | ||
Excitation voltage | V(DC/AC) | 5~12V | ||||
Operating temperature range | ºC | -30 ~ +80 | ||||
Overload capacity | %F.S | 150 | ||||
Capacity | 0.5t~500t | |||||
Protection class | IP67 |