Customization: | Available |
---|---|
Pattern: | Column Cylinder Type |
Transform Type: | 2mv/V |
Still deciding? Get samples of US$ 85/Piece
Request Sample
|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Model |
HMD2015A |
||||
Comprehensive Error mV/v |
40T~100T |
0.5T~30T |
|||
Output Sensitivity %F.S |
0.03 |
0.05 |
0.1 |
0.2 |
0.3 |
Nonlinearity %F.S |
3.0±0.25 |
||||
Repeatability %F.S |
±0.03 |
±0.05 |
±0.1 |
±0.2 |
±0.3 |
Hysteresis %F.S |
0.02 |
0.03 |
0.05 |
0.1 |
0.15 |
Creep (30min) %F.S |
±0.03 |
±0.05 |
±0.1 |
±0.2 |
±0.3 |
Temp Effect On Zero %F.S/10°C |
±0.03 |
±0.05 |
±0.1 |
±0.2 |
±0.3 |
Temp Effect On Output %F.S/10°C |
≤0.003 |
≤0.005 |
≤0.01 |
≤0.02 |
≤0.03 |
Zero Output %F.S |
≤0.003 |
≤0.005 |
≤0.01 |
≤0.02 |
≤0.03 |
Input Resistance Ω |
±1 |
±1 |
±2 |
±5 |
±5 |
Output Resistance Ω |
400±30 |
780±30 |
|||
Insulation Resistance MΩ |
350±3 |
700±3 |
|||
Excitation Voltage V(DC/AC) |
≥5000 |
≥2000 |
≥1000 |
||
Operation Temp Range °C |
5~12 |
||||
Overload Capacity %F.S. |
-30~+80 |
||||
Capacity |
1~200t |
||||
Degree of protection |
IP67 |