Customization: | Available |
---|---|
Pattern: | Bridge Type |
Transform Type: | Resistance Strain |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Capacity(t) | L | L1 | L2 | L3 | B | B1 | B2 | H | H1 | H2 | D | Φ | M |
10 | 200 | 170 | 90 | 60 | 80 | 50 | 50 | 60 | 50 | 17.5 | Φ26 | Φ18 | M16 |
20 | 300 | 240 | 100 | 60 | 120 | 68 | 70 | 120 | 100 | 30.5 | Φ43 | Φ27 | M24 |
50 | 300 | 240 | 100 | 60 | 150 | 68 | 80 | 120 | 100 | 30.5 | Φ43 | Φ27 | M24 |
70 | 300 | 240 | 100 | 60 | 150 | 68 | 80 | 120 | 100 | 30.5 | Φ43 | Φ27 | M24 |
Specification | ||
Model | HMD2011SB/TY2011SB | |
Accuracy class | %F.S | 0.2 |
Output sensitivity | mV/V | 1.0±0.25% |
Nonlinearity | %F.S | ±0.2 |
Repeatability | %F.S | 0.1 |
Hysteresis | %F.S | 0.2 |
Creep (30 min) | %F.S | ±0.2 |
Temperature effect on zero | %F.SºC | ≤0.02 |
Temperature effect on output | %F.SºC | ≤0.02 |
Zero output | %F.S | ±5 |
Input resistance | Ω | 780±30 |
Output resistance | Ω | 700±3 |
Insulation resistance | MΩ | ≥2000 |
Excitation voltage | V(DC/AC) | 5~12V |
Operating temperature range | ºC | -30 ~ +80 |
Overload capacity | %F.S | 200 |
Capacity | 10~70t | |
Protection class | IP66 |
Company Introduction
With 20 years' experiences,we can design and manufacture hundreds of different kinds of load cells:analogy load cell, high temperature load cell, digital load cells and so on. Most of load cells have patents.We guarantee the high quality with competitive price.
Certificated Approval:
EWC, CE, WSF, ROHS...